[vc_row][vc_column width=”2/3″][vc_custom_heading text=”1. Solenoid Valves-VMP SET” font_container=”tag:h2|text_align:left|color:%231e73be” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:400%20regular%3A400%3Anormal”][vc_column_text]1)Technical Parameters
- Nominal Pressure: 2 8MPa
- Test Pressure: 4.2MPa
- Applicable Temperature: -50℃~+ 120℃
- Applicable Medium: Ammonia, Fluorine, Propane, etc
2) Characteristics
- VMP are solenoid servo-operated piston valves, suitable for ammonia and other common fluorinated refrigerants.
- The valves are designed to be mounted between flanges, welded or brazed them to steel or cooper pipes.
- The valves are normally closed with currentless coil,and they open when the coil is powered.
- The degree of opening of VMP valves is function of the differential pressure between the inlet and outlet, so if the pressure difference is △p = 0.3 bar, the main valve will be fully open, and if it is△p = 0.2 ~ 0.3 bar, the degree of opening will be correspondingly proportional to△
- Prepared with hand manual emergency stem
- The standard coil NC type, AC 220V-50/60Hz 10W and MOPD up to 21 Bar, are supplied encapsulated and with DIN 43650 connector.
[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_single_image image=”57496″ img_size=”full” alignment=”center”][vc_single_image image=”57495″ img_size=”full” alignment=”center”][/vc_column][/vc_row][vc_row css=”.vc_custom_1677655102901{margin-top: 40px !important;margin-bottom: 20px !important;}”][vc_column width=”1/4″][vc_row_inner][vc_column_inner width=”1/2″][vc_single_image image=”57498″ img_size=”full” alignment=”center”][/vc_column_inner][vc_column_inner width=”1/2″][vc_single_image image=”57497″ img_size=”full” alignment=”center”][/vc_column_inner][/vc_row_inner][/vc_column][vc_column width=”3/4″][vc_custom_heading text=”2. Pressure Control Pilots-ACVP-H” font_container=”tag:h2|text_align:left|color:%231e73be” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:400%20regular%3A400%3Anormal”][vc_column_text]1)Technical Parameters
- Nominal Pressure: 2 8MPa
- Test Pressure: 4.2MPa
- Applicable Temperature: -50℃~+ 120℃
- Applicable Medium: Ammonia, Fluorine, Propane, etc
2) Characteristics
- The Pilots ACVP-H are used as constant pressure regulators, mounted directly over main valves AM1 or AM3 but can be also mounted on a housing valve ACVH in a external line to control one or more AM or RAK valves.
- The Pilots ACVP-H working in higher pressure with a, range of regulation of 4 Bars to 25 Bars.
- Turning the regulating spindle clockwise, increases the opening pressure of the pilot, (thus the condensating pressure and temperature), and they decrease when we turn the spindle anticlockwise.
- ACVP-H pilot valve is used to keep AM main valve inlet pressure constant. It can also be used as a safety valve, for example, to prevent excessive pressure due to the presence of effusion.
The screw must be replaced[/vc_column_text][/vc_column][/vc_row][vc_row css=”.vc_custom_1677655102901{margin-top: 40px !important;margin-bottom: 20px !important;}”][vc_column][vc_custom_heading text=”3. Forged Steel Filter” font_container=”tag:h2|text_align:left|color:%231e73be” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:400%20regular%3A400%3Anormal”][vc_column_text]Technical Parameters
- Nominal Pressure: 4.0MPa
- Test Pressure: 6.0MPa
- Applicable Temperature: -50℃~+ 150℃
- Applicable Medium: Ammonia, Fluorine, Propane, etc
[/vc_column_text][vc_row_inner][vc_column_inner width=”1/2″][vc_column_text]1) FIAY15-150-D Forged Steel Straight-through Filter
Name | Type | Size(mm) | Weight | ||||
ɸD | ɸD1 | L | ɸD0 | H1 | |||
Straight- through Filter |
FIAY 15-D | 21 | 15 | 106 | 65 | 87 | 1 |
FIAY 20-D | 25 | 20 | 106 | 65 | 89 | 1.1 | |
FIAY 25-D | 32 | 25 | 128 | 75 | 106 | 1.5 | |
FIAY 32-D | 38 | 32 | 128 | 75 | 110 | 1.7 | |
FIAY 40-D | 45 | 40 | 165 | 95 | 140 | 3 | |
FIAY 50-D | 57 | 50 | 165 | 95 | 146 | 3.3 | |
FIAY 150-D | 159 | 149 | 370 | 219 | 355 |
[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/2″][vc_single_image image=”57500″ img_size=”full” alignment=”center”][vc_single_image image=”57499″ img_size=”full” alignment=”center”][/vc_column_inner][/vc_row_inner][vc_row_inner][vc_column_inner width=”1/2″][vc_column_text]
- 2)FIAT15-150-D Forged Steel Right-angle Filter
Name | Type | Size(mm) | Weight | ||||
ɸD | ɸD1 | L | ɸD0 | H1 | |||
Right-angle Filter |
FIAT 15-D | 21 | 15 | 40 | 65 | 92 | 0.9 |
FIAT 20-D | 25 | 20 | 40 | 65 | 92 | 0.9 | |
FIAT 25-D | 32 | 25 | 51 | 75 | 110 | 1.2 | |
FIAT 32-D | 38 | 32 | 51 | 75 | 110 | 1.4 | |
FIAT 40-D | 45 | 40 | 60 | 95 | 138 | 2.4 | |
FIAT 50-D | 57 | 50 | 64 | 95 | 138 | 2.7 | |
FIAT 150-D | 159 | 149 | 145 | 219 | 300 |
[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/2″][vc_single_image image=”57501″ img_size=”full” alignment=”center”][vc_single_image image=”57502″ img_size=”full” alignment=”center”][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row css=”.vc_custom_1677655102901{margin-top: 40px !important;margin-bottom: 20px !important;}”][vc_column][vc_custom_heading text=”4. Cast Steel Stop Valve” font_container=”tag:h2|text_align:left|color:%231e73be” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:400%20regular%3A400%3Anormal”][vc_column_text] Technical Parameters
- Nominal Pressure: 4.0MPa
- Test Pressure: 6.0MPa
- Applicable Temperature: -50℃~+ 150℃
- Applicable Medium: Ammonia, Fluorine, Propane, etc
[/vc_column_text][vc_row_inner][vc_column_inner width=”1/2″][vc_column_text]1) RVY100-250-D Cast Steel Straight-through Stop Valve
Name | Type | Size(mm) | Weight | ||||
ɸD | L | H1 | H | ɸD0 | |||
Straight-through Stop Valve |
RVY100-D | 108 | 264 | 340 | 375 | 156 | 16 |
RVY125-D | 133 | 322 | 405 | 450 | 193 | 30 | |
RVY150-D | 159 | 370 | 480 | 540 | 219 | 39 | |
RVY200-D | 219 | 464 | 615 | 680 | 276 | 90 | |
RVY250-D | 273 | 550 | 715 | 790 | 334 | 110
|
[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_single_image image=”57504″ img_size=”full” alignment=”center”][/vc_column_inner][vc_column_inner width=”1/4″][vc_single_image image=”57503″ img_size=”full” alignment=”center”][/vc_column_inner][/vc_row_inner][vc_row_inner][vc_column_inner width=”1/2″][vc_column_text]2)SRT15-80-D Forged Steel Right-angle Control Valve
Name | Type | Size(mm) | Weight | ||||
ɸD | L | H1 | H | ɸD0 | |||
Right-angle Control Valve |
SRT 15-D | 21 | 35 | 135 | 150 | 60 | 0.6 |
SRT 20-D | 27 | 45 | 155 | 170 | 60 | 1.1 | |
SRT 25-D | 34 | 45 | 155 | 170 | 60 | 1.2 | |
SRT 32-D | 42 | 51 | 180 | 205 | 80 | 2 | |
SRT 40-D | 48 | 55 | 195 | 225 | 80 | 2.4 | |
SRT 50-D | 57 | 60 | 215 | 240 | 100 | 3.6 | |
SRT 65-D | 76 | 70 | 240 | 275 | 120 | 5.6 | |
SRT 80-D | 89 | 90 | 280 | 315 | 160 | 9 |
[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_single_image image=”57506″ img_size=”full” alignment=”center”][/vc_column_inner][vc_column_inner width=”1/4″][vc_single_image image=”57505″ img_size=”full” alignment=”center”][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row css=”.vc_custom_1677655102901{margin-top: 40px !important;margin-bottom: 20px !important;}”][vc_column][vc_custom_heading text=”5. Forged Steel Control Valve” font_container=”tag:h2|text_align:left|color:%231e73be” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:400%20regular%3A400%3Anormal”][vc_column_text]Technical Parameters
- Nominal Pressure: 2.5MPa
- Test Pressure: 3.75MPa
- Applicable Temperature: -50℃~+ 150℃
- Applicable Medium: Ammonia, Fluorine, Propane, etc
[/vc_column_text][vc_row_inner][vc_column_inner width=”1/2″][vc_column_text]1)SRY15-80-D Forged Steel Straight-through Control Valve
Name | Type | Size(mm) | Weight | ||||
ɸD | L | H1 | H | ɸD0 | |||
Straight-through Control Valve |
SRY 15-D | 21 | 90 | 110 | 120 | 60 | 0.65 |
SRY 20-D | 27 | 120 | 130 | 140 | 60 | 1.2 | |
SRY 25-D | 34 | 120 | 130 | 140 | 60 | 1.4 | |
SRY 32-D | 42 | 128 | 155 | 175 | 80 | 2.1 | |
SRY 40-D | 48 | 145 | 170 | 195 | 80 | 2.7 | |
SRY 50-D | 57 | 148 | 205 | 225 | 100 | 4.3 | |
SRY 65-D | 76 | 176 | 240 | 265 | 120 | 6.8 | |
SRY 80-D | 89 | 216 | 265 | 310 | 160 | 11.5 |
[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_single_image image=”57508″ img_size=”full” alignment=”center”][/vc_column_inner][vc_column_inner width=”1/4″][vc_single_image image=”57507″ img_size=”full” alignment=”center”][/vc_column_inner][/vc_row_inner][vc_row_inner][vc_column_inner width=”1/2″][vc_column_text]2) RVT100-300-D Cast Steel Right-angle Stop Valve
Name | Type | Size(mm) | Weight | ||||
ɸD | L | H1 | H | ɸD0 | |||
Right-angle Stop Valve |
RVT100-D | 108 | 106 | 325 | 375 | 156 | 14 |
RVT125-D | 133 | 128 | 395 | 460 | 193 | 27 | |
RVT150-D | 159 | 145 | 460 | 545 | 219 | 35 | |
RVT200-D | 219 | 180 | 550 | 645 | 276 | 73 | |
RVT250-D | 273 | 210 | 620 | 725 | 334 | 100 | |
RVT300-D | 325 | 240 | 655 | 760 | 384 | 140 |
[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_single_image image=”57509″ img_size=”full” alignment=”center”][/vc_column_inner][vc_column_inner width=”1/4″][vc_single_image image=”57510″ img_size=”full” alignment=”center”][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column width=”2/3″][vc_custom_heading text=”6. Check Valve – CVD-A” font_container=”tag:h2|text_align:left|color:%231e73be” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:400%20regular%3A400%3Anormal”][vc_column_text]Technical Parameters
- Nominal Diameter: DN15-DN150
- Nominal Pressure: 4.0MPa
- Applicable Medium: R12, R22, R502, R134a, R404a, R507, R717 and other refrigerants
- Applicable Temperature: -46 ℃~ + 150 ℃
- Structure Form: Angle Type Structure code is A Straight Type Structure code is S
[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_row_inner][vc_column_inner width=”1/2″][vc_single_image image=”57512″ img_size=”full” alignment=”center”][/vc_column_inner][vc_column_inner width=”1/2″][vc_single_image image=”57511″ img_size=”full” alignment=”center”][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row css=”.vc_custom_1677659460597{margin-top: 20px !important;}”][vc_column width=”2/3″][vc_custom_heading text=”7. Stop Check Valve -SCV-A” font_container=”tag:h2|text_align:left|color:%231e73be” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:400%20regular%3A400%3Anormal”][vc_column_text]Technical Parameters
- Nominal Diameter: DN15-DN150
- Nominal Pressure: 4.0MPa
- Applicable Medium: R12, R22, R502, R134a, R404a, R507, R717 and other refrigerants
- Applicable Temperature: -46 ℃~ + 150 ℃
- Structure Form: Angle Type Structure code is A Straight Type Structure code is S
[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_row_inner][vc_column_inner width=”1/2″][vc_single_image image=”57514″ img_size=”full” alignment=”center”][/vc_column_inner][vc_column_inner width=”1/2″][vc_single_image image=”57513″ img_size=”full” alignment=”center”][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column width=”2/3″][vc_custom_heading text=”8. Motor Valve-DFMV-A” font_container=”tag:h2|text_align:left|color:%231e73be” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:400%20regular%3A400%3Anormal”][vc_column_text]Technical Parameters
- Analog Signal 0-10V, 4-20mA, PLC bus control mode;
- Modular design, easy to install, maintain and repair;
- Grade 5 outer seal structure ensures zero leakage;
- Temperature Range: -46 ℃ ~ + 150 ℃
- Power Supply Voltage: 24V
- Nominal Diameter: DN20-DN125
- Nominal Pressure: 4.0MPa
- Structure Form: Angle Type Structure’s code is A Straight Type Structure’s code is B
Instruction
Used for Control Valves in industrial refrigeration pipelines easy to realize automatic control .[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_row_inner][vc_column_inner width=”1/2″][vc_single_image image=”57516″ img_size=”full” alignment=”center”][/vc_column_inner][vc_column_inner width=”1/2″][vc_single_image image=”57515″ img_size=”full” alignment=”center”][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row css=”.vc_custom_1677659477433{margin-top: 20px !important;}”][vc_column width=”2/3″][vc_custom_heading text=”9. Overflow Valve-OFD” font_container=”tag:h2|text_align:left|color:%231e73be” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:400%20regular%3A400%3Anormal”][vc_column_text]Technical Parameters
- Nominal Diameter: DN20-DN25
- Pressure Adjustment Range: 2-6.5bar 3.5-8bar
- Applicable Medium: R12,R22,R502,R134a,R404a,R507,R717 and other refrigerants
- Applicable Temperature: -46 ℃~ + 150 ℃
Model | Nominal Diameter (DN) | Size (mm) | Connection | |||||
ɸD | ɸD1 | L | L1 | H | H1 | |||
OFD | 20 | 26.9 | 38 | 45 | 60 | 250.5 | 49.5 | Butt welding |
25 | 33.7 | 38 | 45 | 60 | 250.5 | 49.5 |
[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_row_inner][vc_column_inner width=”1/2″][vc_single_image image=”57517″ img_size=”full” alignment=”center”][/vc_column_inner][vc_column_inner width=”1/2″][vc_single_image image=”57518″ img_size=”full” alignment=”center”][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row css=”.vc_custom_1677659486234{margin-top: 20px !important;}”][vc_column width=”2/3″][vc_custom_heading text=”10. Liquid Switch-LS50″ font_container=”tag:h2|text_align:left|color:%231e73be” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:400%20regular%3A400%3Anormal”][vc_column_text]Technical Parameters
- Nominal Diameter: DN20-DN25
- Refrigerant: Applicable to various non-flammable refrigerants such as ammonia and non-corrosive gases and liquids, but pay attention to the use of corresponding sealing materials. Flammable hydrocarbons are not recommended
- Temperature Range: -46℃~ +65℃
- Pressure Range: Max.Working pressure: 28 bar g
- Electrical Parameters: Microelectronic single pole double throw switch
- 250 V a.c / 10A 30V d.c / 5A
- It has two functions: normally open and normally closed
- DIN43650 Cable Standard : PG11, 8-10mm
- Cable: 1.5mm (16AWG) +PE, IP65
- Nominal Diameter Of External Flange Interface: DN20, DN25
- Float Level Difference: 12.5- 50mm, Factory default 50mm, Adjustment the step length12.5mm
[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_row_inner][vc_column_inner width=”1/2″][vc_single_image image=”57520″ img_size=”full” alignment=”center”][/vc_column_inner][vc_column_inner width=”1/2″][vc_single_image image=”57519″ img_size=”full” alignment=”center”][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_icon icon_fontawesome=”fas fa-caret-down” align=”center”][vc_column_text]
Valves widely used in refrigerated storage and freezing systems in the industries of cooling, refrigeration and air-conditioning as well as the industries of food, beverage, bear, pharmaceutical, ship-building, gas, chemical, petroleum. etc. For more, please contact us.
[/vc_column_text][/vc_column][/vc_row]